Automatic EVA Laying Machine Technical Requirements and Environmental Precautions

- Apr 26, 2018-

In the process of operating the automatic EVA laying machine, the common feeding method for the equipment is the air rising shaft wear material, the cylinder lifting mechanism lifts the material shaft, and is equipped with an infrared proofreading. At the same time, its connection and receipt methods are pneumatic clips. During the operation of the automatic EVA laying machine, the cutting mode of the automatic EVA laying machine generally uses a hob cutter. The punching mode is a mode in which the guide rod cylinder and the cutter cooperate.

 

In the market, the cutting size of the automatic EVA laying machine is usually between 500 and 2000 mm. The material reel specifications are generally 76mm inner diameter, outer diameter ≤600m, and maximum load 200kg. The cutting precision of the equipment can reach a size error of ±2mm, and the diagonal dimension error is within 3mm. Because the user's production requirements are different, the hole-cutting tools used are also different. The installation dimensions of the different hole-opening tools are standardized and the switching is quick.

 

Automatic EVA laying machine has shown good working performance in production. Its main function is to automatically feed EVA coils, automatically cut and punch holes, and lay them on the glass on the initial positioning stage. It should be noted that, in order to ensure the safety of production, during the use of the equipment, the staff should pay attention to the inspection and inspection of the safety shields, doors, and lids, and they are not damaged. If it is damaged, it must be replaced or repaired.

 

At the same time when installing the automatic EVA laying machine, we must also choose the suitable installation environment. First, we must pay attention to the ground around the equipment to prevent the presence of oil and water to prevent the operator from slipping. In addition, during the work, the floor shall be free of obstacles within a range of 0.8 meters from the machine to avoid tripping and falling during operation.

 

Finally, when operating the automatic EVA laying machine, measures must also be taken to ensure the safe operation of the control system. First, the transformer, relay, motor, and high voltage terminal in the electrical box of the electrical control system must not be touched. Second, after the voltage is disconnected, there will be a residual voltage within a short time. Use a multimeter to confirm the voltage before touching the terminal. Work; When working in the equipment cabinet, you must disconnect the main power switch of the access machine.